Новый тестовый ESP32-скетч вне проекта

This commit is contained in:
AidarKC
2026-10-07 08:47:28 +03:00
parent acd5d4406d
commit b1c42efa82
3 changed files with 120 additions and 33 deletions
@@ -71,11 +71,14 @@ After tapping `START`:
- one breathing cycle is measured from one stable `EXHALE` start to the next stable `EXHALE` start
- contact changes use an 80 ms debounce
- UI shows current cycle duration, arithmetic average duration over the last 5 completed cycles, and elapsed time from start
- the physical user/BOOT button cycles the short-cycle limit through `5`, `7`, `10`, `15`, `20` seconds
- the physical user/BOOT button opens and closes the settings screen
- settings screen has three touch sliders: limit `5/7/10/15/20` seconds, quiet cycle tick volume `0..10`, and alert volume `0..10`
- the working screen uses a static frame and only updates value regions to avoid display flicker
- the `START` button is a flat rounded rectangle with a border; there is no pause button in this version
- every new cycle start plays one quiet confirmation beep
- if the arithmetic average of the last up to 5 completed cycles is shorter than the selected limit, the device plays warning beeps: 1 beep for the first short average in a row, 2 beeps for the second, up to 5 beeps
- completed cycles shorter than 1.5 seconds are ignored as contact bounce
- if the current cycle exceeds 60 seconds, the main screen shows `PAUSE`; that long cycle is skipped and the next `EXHALE` start begins a fresh cycle from zero
- reset/power cycle restores ordinary native USB boot
This version is intended to monitor breathing cadence from a dry-contact USB D-/D+ sensor.