SHA256
Улучшить Arweave-синхронизацию и ротацию ключей
Улучшено скачивание блоков из Arweave и обработка канонической цепочки. Ротация ключей переведена на новую схему с пересборкой публичных каналов; личные сообщения пока не меняются.
This commit is contained in:
@@ -0,0 +1,81 @@
|
||||
# USB contact sensor test
|
||||
|
||||
Diagnostic sketches:
|
||||
|
||||
- `main-device/test_sketches/usb_contact_sensor_test/usb_contact_sensor_test.ino`
|
||||
- `main-device/test_sketches/usb_contact_sensor_debug_test/usb_contact_sensor_debug_test.ino`
|
||||
- `main-device/test_sketches/usb_contact_screen_start_stub/usb_contact_screen_start_stub.ino`
|
||||
|
||||
## Purpose
|
||||
|
||||
Use the ESP32-S3 native USB data pair as a removable two-wire dry-contact input without making this mode persistent.
|
||||
|
||||
- `GPIO19` = native USB `D-`
|
||||
- `GPIO20` = native USB `D+`
|
||||
|
||||
## Boot behavior
|
||||
|
||||
Every normal reset starts in ordinary native USB mode. The sketch does not save sensor mode in NVS or any other persistent storage.
|
||||
|
||||
Initial screen:
|
||||
|
||||
- title: `USB CONTACT TEST`
|
||||
- mode: `USB mode`
|
||||
- state: `READY`
|
||||
- action button: `Start`
|
||||
|
||||
Until `Start` is pressed, the sketch does not reconfigure GPIO19/20.
|
||||
|
||||
## Sensor mode
|
||||
|
||||
After `Start`:
|
||||
|
||||
- GPIO19 is configured as `OUTPUT LOW`
|
||||
- GPIO20 is configured as `INPUT_PULLUP`
|
||||
- a passive switch/contact is connected between USB `D-` and `D+`
|
||||
- open contact => GPIO20 reads HIGH => UI shows `OPEN`
|
||||
- closed contact => GPIO20 reads LOW => UI shows `CLOSED`
|
||||
- contact changes use a 20 ms debounce
|
||||
|
||||
Native USB data is intentionally unavailable while sensor mode owns GPIO19/20. The UI warns not to connect the port to a computer in this state.
|
||||
|
||||
The action button changes to `Restart to USB`. Pressing it calls `ESP.restart()`; after reboot normal USB mode is restored.
|
||||
|
||||
A physical reset/power cycle has the same effect. The ESP32-S3 ROM download mode remains available through the board's BOOT procedure if recovery is needed.
|
||||
|
||||
## Debug version
|
||||
|
||||
The debug sketch starts in normal USB mode and shows raw touch diagnostics on screen. The on-screen `START` button is intentionally diagnostic only: it confirms touch/LVGL button events and does not reconfigure GPIO19/20.
|
||||
|
||||
Sensor mode starts from the physical BOOT/user button on GPIO0, active LOW. The button is debounced for 35 ms, then the UI shows `START RECEIVED` / `STARTING...`, waits 250 ms so the visual transition is rendered, and only then reconfigures USB D-/D+ as the contact input.
|
||||
|
||||
While in sensor mode, pressing the BOOT/user button again restarts the device and returns normal USB mode on the next boot.
|
||||
|
||||
## GFX breath monitor version
|
||||
|
||||
The `usb_contact_screen_start_stub` sketch is a breath monitor firmware based on the production `Arduino_GFX` display path instead of LVGL.
|
||||
|
||||
Initial screen:
|
||||
|
||||
- title: `USB CONTACT`
|
||||
- title in the current version: `BREATH MONITOR`
|
||||
- state: `READY`
|
||||
- action button: `START`
|
||||
|
||||
After tapping `START`:
|
||||
|
||||
- GPIO19 is configured as `OUTPUT LOW`
|
||||
- GPIO20 is configured as `INPUT_PULLUP`
|
||||
- closed contact is treated as `EXHALE`
|
||||
- open contact is treated as `INHALE`
|
||||
- one breathing cycle is measured from one stable `EXHALE` start to the next stable `EXHALE` start
|
||||
- contact changes use an 80 ms debounce
|
||||
- UI shows current cycle duration, arithmetic average duration over the last 5 completed cycles, and elapsed time from start
|
||||
- the physical user/BOOT button cycles the short-cycle limit through `5`, `7`, `10`, `15`, `20` seconds
|
||||
- the working screen uses a static frame and only updates value regions to avoid display flicker
|
||||
- the `START` button is a flat rounded rectangle with a border; there is no pause button in this version
|
||||
- every new cycle start plays one quiet confirmation beep
|
||||
- if the arithmetic average of the last up to 5 completed cycles is shorter than the selected limit, the device plays warning beeps: 1 beep for the first short average in a row, 2 beeps for the second, up to 5 beeps
|
||||
- reset/power cycle restores ordinary native USB boot
|
||||
|
||||
This version is intended to monitor breathing cadence from a dry-contact USB D-/D+ sensor.
|
||||
Reference in New Issue